StarLighter Blood Direct PCR Mix utilizes a unique PCR buffer system that effectively minimizes the effects of inhibitors in blood on amplification. This eliminates the need for DNA purification or sample processing, allowing direct PCR using whole blood samples as templates. StarLighter Blood Direct PCR Mix is a 2× ready-to-use PCR premix containing a highly efficient DNA polymerase, dNTPs, MgCl2, reaction buffer, PCR enhancer, and stabilizer. Simply add template, primers, and water to initiate PCR amplification. This kit is compatible with EDTA-anticoagulated blood samples stored under various storage conditions and can be used for singleplex or multiplex direct blood amplification.
Product Introduction StarLighter Probe qPCR Mix (High GC) is a specialized premix for probe-based qPCR. It contains a premium hot-start Taq DNA Polymerase with enhanced template affinity, combined with a buffer optimized for amplification of GC-rich targets. This effectively suppresses nonspecific amplification, significantly increasing qPCR efficiency and sensitivity. The kit generates excellent amplification curves across a wide concentration range, enabling accurate quantitative and qualitative analysis of target genes and SNP detection. It offers excellent reproducibility, high reliability, and compatibility with a wide range of qPCR probes. The reference dye ROX is provided with the kit. This product is a 2× premix that only requires the addition of primers, probes, and templates. It is easy to use and compatible with rapid protocols, shortening detection time. Product components
Note: Please store at the recommended storage temperature and avoid repeated freezing and thawing. Storage and transportation conditions Store at -25 ~ -15℃, transport at < 0℃. Product Application Gene expression analysis; SNP and allele typing; validation of sequencing and microarray results; Precautions
experiment process
![]() b. The final concentrations of primers and probes in the reaction can be adjusted between 1 and 1 μM. c. It is best to prepare the common components into a premixed solution before use. d. ROX is used according to the model. 3. Close the tube cap and centrifuge briefly. 2. Reaction Procedure qPCR standard procedure
Common Problems and Solutions
Answer: ① If the amplification curve is not smooth, you need to recalibrate the system, increase the template concentration, and check whether ROX is used incorrectly. ②If the amplification curve breaks or declines, it may be caused by too high template concentration or inappropriate baseline selection range. You can reduce the template or reset the baseline. ③If the individual amplification curve drops suddenly, there may be bubbles in the reaction tube, so it should be centrifuged before loading.
Answer: ① It may be that the number of cycles is not enough: 40 cycles are generally set, but too many cycles will increase the background signal and reduce the credibility of the data. ② Confirm whether signal acquisition is set in the program: the two-step method generally collects signals during the annealing/extension stage; the three-step method collects signals during the extension stage. ③ Primer degradation: PAGE detection excludes the possibility of its degradation. ④The template concentration is too low: reduce the dilution and repeat the experiment, starting with a high concentration. ⑤ Template degradation: re-prepare the template.
Answer: ① Low amplification efficiency: Optimize reaction conditions, try three-step amplification or redesign synthetic primers. ② Low template concentration: Reduce the template dilution and start with high concentration. ③ Template degradation: re-prepare the template. ④The PCR product is too long: The recommended PCR product length is 80 to 150 bp. ⑤ PCR inhibitors are present: If the template is involved, increase the template dilution multiple or prepare a new template.
Answer: ① Contamination of the reaction system: Repeat the experiment with new reagents, water, primers, etc.; operate in a clean bench to reduce aerosol contamination. ② Improper primer design: Redesign and synthesize primers.
Answer: ① Sample addition error: increase the template dilution multiple and increase the sample addition volume. ②Degradation of standard sample: re-prepare the standard sample. ③The template concentration is too high: increase the template dilution multiple. 6. What should I do if the experimental reproducibility is poor?Answer: ① Inconsistent sample volume: Use a better pipette; dilute the template by a high multiple and increase the sample volume appropriately. ②The template concentration is too low: The lower the template concentration, the worse the repeatability. Reduce the template dilution or increase the sample volume. |
||||||||||||||||||||